Infomation

2018/09/03

Points of caution concerning hydraulic oil refueling in air riveters

Thank you for your continued patronage of this company.

Mistakes undertaken during refueling of hydraulic pressure oil in our company’s air riveters can result in damage to the machine body and effect performance. With this in mind, the following information has been included in instruction manuals, and we ask our customers to please take note of the operation as indicated.

 

[Cautionary notes uniform to various models]

• Be sure to stop the air supply before operation.

• Use LOBSTER Hydraulic Pressure Oil B10012 for the oil.

• After refueling oil, be sure to confirm that there is no loosening of items in each of the jaw case sections.

• During operation, be sure to use the proper air pressure (0.5–0.6 MPa)

 

Operate only after confirming operation is in line with the points of caution described in the instruction manual* for the given machine.

(Please contact us if the model you are using is not listed below)

* The instruction manual is available for viewing by clicking the model listed below. (Only the models that are underlined are available)

 
Model Points of Caution
R1A1
R1A2

• Be sure to remove the frame head before refueling.

• Confirm that none of the parts in the vicinity of the jaw case are loose.
• After refueling and replacing the frame head, loosen the oil retaining screw section and remove excess hydraulic oil.

AR-011S
AR-011M
AR-011H

AR-011MX
AR-011HX

ARV-011M
ARV-015S

• Be sure to remove the frame head before refueling.

• After refueling, confirm that the jaw case is in its set position, and that none of the related parts are loose.

ARV-015M
ARV-015MX

• Be sure to remove the frame head before refueling.

• After refueling, loosen the oil retaining screw section and remove excess hydraulic oil.

• After removing the excess hydraulic oil, confirm that the jaw case is in its set position, and that none of the related parts are loose.

AR-2000S
AR-2000M
AR-2000H

AR-2000SV
AR-2000MV
AR-2000HV

• Be sure to remove the frame head before refueling.

• After refueling, loosen the oil retaining screw section and remove excess hydraulic oil.

• After removing the excess hydraulic oil, confirm that the jaw case is in its set position, and that none of the related parts are loose.

AR-3000EV

• Be sure to remove the frame head before refueling.

• After refueling using the oil feeder, firmly close the oil retaining screw and pull out the oil piston.

• Loosen the oil retaining screw and remove any excess hydraulic oil from the exposed oil piston.
AR-022M
ARV-022M
ARV-025M

• Remove the cap or oil tank cap, and fill the rubber tank.

• When the rubber tank is in a slightly collapsed state, this is the correct oil amount

• After refueling, confirm that none of the parts related to the jaw case are loose.

Angle Riveter
AR2000A-90
AR2000A-45
AR2000A-00

• Before refueling, be sure to remove the angle head frame.

• After refueling, be sure to loosen the oil retaining screw and remove any excess hydraulic oil.

If any of the above points are unclear, please consult our call center for more information.

Lobtex Co., Ltd. Call Center               TEL 072-980-1111    FAX 072-980-1166

Infomation index

M:GoogleAnalytics

GO TO PAGE TOP